Trial Protocol Evaluates Continuous Glucose Monitoring for Intensive Care
A newly published study protocol outlines a clinical trial designed to evaluate the implementation and effectiveness of continuous glucose monitoring within an intensive care setting. Researchers led by Eileen R. Faulds, Kathleen M. Dungan, and colleagues publ
Illustrative imageA newly published study protocol outlines a clinical trial designed to evaluate the implementation and effectiveness of continuous glucose monitoring within an intensive care setting. Researchers led by Eileen R. Faulds, Kathleen M. Dungan, and colleagues published the protocol in BMC Health Services Research to investigate continuous glucose monitoring alongside standard testing. The mixed methods hybrid type II effectiveness-implementation investigation focuses on evaluating both patient health outcomes and the practical feasibility of deploying continuous glucose monitors for patients requiring intravenous insulin therapy.
Over the past two decades, continuous glucose monitoring has demonstrated clear benefits in outpatient clinical practice, showing established improvements in outpatient glycemic control and broader patient outcomes. Despite those documented outpatient successes, continuous glucose monitoring technologies currently lack regulatory approval for inpatient hospital use. Within hospital wards, point-of-care glucose monitoring has remained the standard of care since the late 1980s. However, implementation of point-of-care testing in inpatient environments remains insufficient, frequently complicated by missed glucose tests and irregular testing schedules.
Both hyperglycemia and hypoglycemia occur frequently in inpatient settings and are consistently linked with heightened patient morbidity, higher mortality rates, prolonged lengths of hospital stay, and increased overall hospital costs. Continuous glucose monitoring devices offer specific automated capabilities designed to address these hazards, including continuous glucose measurements, customizable hyperglycemia and hypoglycemia threshold alarms, predictive alarms for impending hypoglycemia, and real-time trend data. These features hold promise for improving glycemic stability, enhancing patient outcomes, and alleviating nursing burden, though empirical inpatient research remains necessary.
The trial protocol establishes a combined continuous glucose monitoring plus point-of-care protocol, designated as the CGM plus POC protocol. Throughout the study, bedside clinicians will utilize the Dexcom G6 continuous glucose monitoring system alongside standard point-of-care testing to guide clinical decisions.
The clinical investigation pursues four distinct research questions across its implementation framework. First, the investigators seek to determine the clinical utility, procedural fidelity, and clinical adoption of the Dexcom G6 device when used to inform insulin dosing decisions within the combined protocol. Second, the researchers will assess the direct effects of continuous glucose monitoring implementation on nursing workload and explore broader factors shaping bedside care delivery. This operational assessment will collect data through structured surveys administered to medical intensive care unit nurses and through an in-depth focus group conducted with ten staff nurses.
Third, the trial will compare glycemic control metrics among patients managed in the continuous monitoring intensive care unit against a historical control group of intensive care patients who received traditional point-of-care glucose monitoring alone. Fourth, as an exploratory objective, the study team will examine wider hospitalization outcomes and perform a comprehensive economic evaluation to determine the institutional costs of delivering continuous glucose monitoring implementation in critical care.
By integrating effectiveness and implementation methodologies, the hybrid trial aims to generate simultaneous empirical data on clinical efficacy and operational feasibility, potentially supporting the broader adoption of continuous glucose monitoring as an inpatient standard of care. The single-arm trial is registered in the public clinical trials registry at ClinicalTrials.gov under the registration identifier NCT05571397, having been formally registered on June 13, 2018.
Subject of Research: Clinical trial protocol for continuous glucose monitoring in intensive care
Article Title: Expanding use of continuous glucose monitoring beyond COVID in critical care: study protocol for a hybrid implementation trial
Article References: Faulds, E. R., Lee, B., Rasul, A., Jones, L., McNett, M., Exline, M., Shoben, A., Lin, C. J., & Dungan, K. M. (2026). Expanding use of continuous glucose monitoring beyond COVID in critical care: study protocol for a hybrid implementation trial. BMC Health Services Research. https://doi.org/10.1186/s12913-026-16238-8
Image Credits: AI Generated
DOI: 10.1186/s12913-026-16238-8
Keywords: continuous glucose monitoring, medical intensive care unit, study protocol, hybrid effectiveness-implementation, intravenous insulin, point-of-care glucose monitoring, Dexcom G6, glycemic control, hypoglycemia, hyperglycemia, nursing workload, inpatient glucose monitoring, clinical utility, economic evaluation, historical control, ClinicalTrials.gov NCT05571397, staff nurse focus group